Electric Power:

G3520 2500kW Gas Generator Set



Equipment

  • Air Inlet
    • Two-element single-stage air cleaner with enclosure and service indicator
  • Control Panel
    • EMCP 4.3
  • Cooling
    • Jacket water and SCAC engine-driven pumps
    • Jacket water and SCAC thermostats
  • Exhaust
    • Cat-flanged face outlet on turbocharger
    • Individual exhaust port and turbocharger outlet wired to integrated temperature sensing module (ITSM) with GCEM providing alarms and shutdowns
    • Dry exhaust manifolds, insulated and shielded
  • Fuel System
    • Gas pressure regulator
    • Engine-installed electronic control valve
    • Fuel system is sized for 31.5 to 47.2 MJ/NM3 dry pipeline natural gas with pressure of 10.2 to 34.5KPa to the engine fuel control valve
    • 24V DC energized-to-run (ETR) gas shutoff valve
    • Throttle plate, 24V DC actuator, controlled by GECM
  • General
    • Crankshaft vibration damper and guard
    • Operation and maintenance manuals
    • RH Service
    • Paint- Caterpillar Yellow with high gloss black rails and radiator
    • Parts book
  • Generator
    • SR5
    • Permanent Magnet Excitiation
    • NEMA Class H insulation
    • Winding temperature detectors
    • Integrated voltage regulator (IVR)
    • Anti-condensation space heater
  • Starting/charging
    • Battery with cables and rack (shipped loose)
    • 24V starting motors
    • Electric Starter
    • Jacket water heater
  • Governing System
    • ADEM A4
  • Ignition System
    • Electronic Ignition System (controlled by ADEM A4)
    • Individual Cylinder Detonation Sensitive Timing (DST)
  • Air Inlet
    • Air cleaner with precleaner
  • Control Panel
    • Local alarm module
    • EMCP 4.4
    • Remote annunciator
    • Remote PC monitoring
    • Engine failure relay
    • Local PC monitoring
  • Circuit Breakers
    • 2000A, 2500A, 3000A 3 Pole, UL-100% Rated Masterpact Circuit Breakers
    • 100% rated, 3-pole (UL/CSA/IEC) 5th Digit Rating
    • 3-pole (IEC 947-2 rated)
    • Frame mounting
    • 1600A, 2000A 3 Pole, UL-100% Rated R-Frame Circuit Breakers
    • S LSI, G LSIG, P LSIG-P, 4th Digit Type
  • Cooling
    • Coolant level drain line with valves, fan with guard
    • Package mounted radiator
  • Exhaust
    • 305 mm (12 in.) muffler
    • 305 mm (12in.) elbow
    • 18, 25 dBA Attenuation
    • 305 mm (12 in.) flange
    • 305mm (12 in) spark arresting muffler
  • Fuel System
    • 3, 0-100 kPag, 4-20mA gas train pressure sensors
  • General
    • Digital diagnostic tool
  • Generator
    • Low voltage extension box
    • Bearing temperature detectors
    • European bus bars
    • Cable access box
    • Generator air filter
  • Starting/charging
    • 45A, 24V charging alternator (requires engine driven pumps)
    • 20A, 24VDC battery charger