Diesel Generator Sets:

C4.4 Generator Set

Duty Cycle
Standby, Prime
Aspiration
Turbocharged
Minimum Rating
36 ekW
Maximum Rating
60 ekW

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.



Product Specs

  • Generator Set Specifications

  • Duty Cycle
    Standby, Prime
    Minimum Rating
    36 ekW
    Maximum Rating
    60 ekW
    Voltage
    208 to 600 Volts
    Frequency
    60 Hz
    Speed
    1800 rpm
    Emissions/Fuel Strategy
    U.S. EPA Cert., Tier 3
  • Engine Specifications

  • Aspiration
    Turbocharged
    Engine Model
    C4.4, In-line 4, 4-cycle diesel
    Compression Ratio
    18.2:1
    Governor Type
    Adem™A4
    Fuel System
    Electronic (adjustable)
    Bore
    4.13in
    Displacement
    268.5in
    Stroke
    5in
    Fuel System
    5in
  • Generator Set Dimensions

  • Height - Maximum
    53.6in
    Length - Maximum
    75.8in
    Width - Maximum
    44.1in

Equipment

  • Certificates
    • IBC Seismic and Wind Certifications
  • Circuit Breakers
    • Breakers (100% UL rated)
    • Second circuit breaker box
    • Power perminal strips
    • 3-Pole 100% rated
  • Air Inlet System
    • Air Cleaner
    • Cartridge type air filter
  • Charging System
    • NFPA battery charger UL10A 120VAC
  • Control Panel
    • EMCP 4 Control panel
  • Exhaust System
    • Stub pipe, gaskets, raincap and SAE exhaust flange for customer use - shipped loose
  • Fuel System
    • Standard open set fuel tank / base supplied base, formed steel with single wall integral 8-hour fuel tank
  • Control Panels
    • FSS low fuel level alarm & indication panel circuitry required when sub-base tank is selected
    • NFPA110 bundle includes:
    • WSS1 Low coolant level shut down
    • WCA1 Low coolant temperature alarm
    • A coolant heater, remote annunciator or 0.8 power factor test may be required depending on the application
    • Oil temperature guage and sender
    • PAA1 Panel mounted audible alarm
    • PBC10NU NFPA Battery Charger
    • Ground fault relay
    • Discrete I/O module
    • Remote E-stop button
    • Volt free contacts genset run and common alarm
    • Audible alarm
    • Remote annunciator
    • Low coolant temperature alarm
    • Protective devices:
    • Low coolant level shutdown
    • Overload shutdown via breaker
    • Fuel level reading
  • Generator
    • 12 leads
  • Governing System
    • Mechanical and electrical governing system - model dependent
  • Lube System
    • Lubricating oil
    • Oil drain line with valve
  • Cooling System
    • Coolant drain line with valve
    • Radiator and cooling fan with guards
    • Fan drive, battery charging alternator drive
    • Caterpillar extended life coolant
    • Radiator stone guard
  • General
    • Engine and alternator pre-paint, Caterpillar Yellow
  • Starting/charging System
    • 24V battery with rack and cables
    • Batteries
  • Certificates
    • IBC Seismic and Wind Certifications
  • Alternator System
    • R frame auxilliary winding
  • Air Inlet System
    • Cartridge type air filter
  • Charging System
    • NFPA battery charger UL10A 120VAC
  • Circuit Breakers
    • 3-Pole 100% rated
    • Power perminal strips
    • Breakers (100% UL rated)
    • Second circuit breaker box
  • Control Panels
    • NFPA110 bundle includes: FSS low fuel level alarm & indication panel circuitry required when sub-base tank is selected - WSS1 Low Coolant level shut down - WCA1 Low Coolant temperature alarm - PAA1 Panel mounted audible alarm - PBC10NU NFPA Battery Charger - A coolant heater ,remote annunciator or 0.8 power factor test may be required depending on the application
    • Discrete I/O module
    • Ground fault relay
    • Volt free contacts genset run and common alarm
    • Remote E-stop button
    • Remote annunciator
    • Audible alarm
    • Protective devices: Low coolant temperature alarm - Low coolant level shutdown - Fuel level reading - Overload shutdown via breaker
    • Oil temperature guage and sender
  • Cooling System
    • Radiator transition flange
    • Radiator transition flange
  • Enclosures
    • Sound attenuated enclosure, level 1
    • Sound attenuated enclosure, level 2
    • External emergency stop
    • Panel viewing window
    • Weatherproof enclosure
    • Sound attenuated enclosure, level 1
    • Panel viewing window
    • Sound attenuated enclosure, level 2
    • Weatherproof enclosure
    • External emergency stop
  • Heating Elements
    • Anti-condensation heater
    • Lube oil sump heater
    • Wiring for canopy space heater
    • Battery heater
    • Jacket water heater
    • Coolant heater
    • Anti-condensation heater
    • Battery heater
    • Lube oil sump heater
    • Coolant heater
    • Jacket water heater
    • Wiring for canopy space heater
  • Exhaust System
    • Overhaed silencer mounting kit
    • 10, 25 and 35 dBA silencer systems
    • 10, 25 and 35 dBA silencer systems
    • Overhaed silencer mounting kit
  • Fuel System
    • Emergency vent pipe
    • 5 gallon spill containment
    • 5 gallon fill containment
    • Tank riser
    • 209 and 394 gallon sub-base fuel tanks
    • Tank riser
    • 5 gallon spill containment
    • Emergency vent pipe
    • 209 and 394 gallon sub-base fuel tanks
    • 5 gallon fill containment
  • Generators
    • Permanent magnet generator
    • Permanent magnet generator
  • Mounting System
    • Seismic vibration isolators
    • Seismic vibration isolators
  • Tests
    • 4 Hour factory test
    • Generator test report
    • PGS test report @ 0.8 power factor
    • PGS test report @ 1.0 power factor
    • Generator test report
    • 4 Hour factory test
    • PGS test report @ 0.8 power factor
    • PGS test report @ 1.0 power factor

Request a Quote