Diesel Generator Sets:

C4.4 Generator Set

Height - Maximum
53.6 in
Length - Maximum
75.8 in
Width - Maximum
44.1 in
Minimum Rating
72 ekW

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.



Product Specs

  • Generator Set Dimensions

  • Height - Maximum
    53.6in
    Length - Maximum
    75.8in
    Width - Maximum
    44.1in
  • Generator Set Specifications

  • Minimum Rating
    72 ekW
    Maximum Rating
    100 ekW
    Voltage
    110 to 480 Volts
    Frequency
    60 Hz
    Speed
    1800 rpm
    Emissions/Fuel Strategy
    U.S. EPA Cert., Tier 3
    Duty Cycle
    Standby, Prime
  • Engine Specifications

  • Engine Model
    Cat® C4.4
    Compression Ratio
    16.2:1, 17.25:1, 18.2:1 or 18.3:1
    Governor Type
    Mechanical
    Fuel System
    Direct Injection or Common Rail
    Bore
    4.1in
    Displacement
    268.5in³
    Stroke
    5in
    Aspiration
    Turbocharged
    Fuel System
    5in

Equipment

  • Air Inlet System
    • Air cleaner; light duty with disposable element
    • Air Cleaner
  • Cooling System
    • Fan drive, battery charging alternator drive
    • Caterpillar extended life coolant
    • Coolant drain line with valve
    • Radiator and cooling fan with guards
    • Radiator and cooling fan with guards
    • Coolant drain line with valve
    • Caterpillar extended life coolant
    • Fan drive, battery charging alternator drive
  • Control Panel
    • EMCP 4.1
    • EMCP 4 Control panel
  • Exhaust System
    • Stub pipe, gaskets, raincap and SAE exhaust flange for customer use - shipped loose
    • Stub pipe, gaskets, raincap and SAE exhaust flange for customer use - shipped loose
  • Fuel System
    • Standard open set fuel tank / base supplied base, formed steel with single wall integral 8-hour fuel tank
    • Standard open set fuel tank / base supplied base, formed steel with single wall integral 8-hour fuel tank
  • Generator
    • IP23 protection
    • Voltage regulator (single phase sensing)
    • 12 leads
    • Circuit breaker, IEC, 3 pole, mounted in tower panel
    • Tower panel, IP22, bottom cable entry
    • Segregated low voltage (AC/DC) wiring panel
    • 12 leads
  • Governing System
    • Mechanical and electrical governing system - model dependent
    • Mechanical and electrical governing system - model dependent
  • Lube System
    • Oil drain line with valve
    • Lubricating oil
    • Oil drain line with valve
    • Lubricating oil
  • Mounting System
    • Termination points for coolant and lube oil drain lines
    • Includes lifting provision and drag points
    • Captive linear vibration isolators between base and engine-generator
  • Starting/charging System
    • 24V battery with rack and cables
    • Batteries
    • 24V battery with rack and cables
  • General
    • Engine and alternator pre-paint, Caterpillar yellow
    • Engine and alternator pre-paint, Caterpillar Yellow
  • Alternator System
    • Anti-condensation heater
    • Quadrature droop kit
    • 3 phase sensing
    • R frame auxilliary winding
    • LC frame alternator with coastal insulation protection
    • Permanent magnet
    • LC frame alternator
    • R frame auxilliary winding
  • Circuit Breakers
    • Circuit Breaker Upgrades - 4 Pole circuit reaker to 250A, 400A and 630 A
  • Cooling System
    • Low coolant temp alarm
    • Coolant heater
    • Low coolant level shutdown
  • Control Panel Options
    • Earth fault (2 wire only)
    • Control panel heater
    • Panel mounted audible alarm
    • Volt free contacts
    • Voltage adjust potentiometer
    • Overload shutdown via breaker
    • Earth leakage (2 wire only)
    • EMCP 4.2
    • Emergency stop with key
    • Speed adjust potentiometer
    • Battery charger
  • Enclosures
    • Rental pack - CAE rental option only
    • Sound attenuated Level 2 enclosure
    • Sound attenuated Level 1 (galv)
  • European Certifications
    • Upgrade to STD set for CE
  • Fuel System
    • Low fuel level shutdown
    • Compact skidbase for open set
    • Open set narrow base
    • Bunded fuel tank
    • Low fuel level alarm
    • High fuel level alarm
    • Skidbase for CALG enclosure sets
  • Global Certifications
    • Certification for CIS
  • Mounting Options
    • Electronic governor
    • External single point lift - enclosure
    • Silencer installation kit
    • Industrial silencer
    • Battery removal
  • Special Packing/inspectons For Shipment
    • PGS test report @ 1.0 power factor
    • PGS test report @ 0.8 power factor
  • General - Accessories / Miscellaneous
    • Packing case - canopied set
    • Packing case - compact set
    • Stone guards / rad trans flange

Request a Quote

Find a Boyd CAT
Location or Rep Near You