Diesel Generator Sets:

C32 (60 Hz)

Minimum Rating
830 ekW
Maximum Rating
1250 ekW
Voltage
220 to 4160 Volts
Frequency
60 Hz

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.



Product Specs

  • Generator Set Specifications

  • Minimum Rating
    830 ekW
    Maximum Rating
    1250 ekW
    Voltage
    220 to 4160 Volts
    Frequency
    60 Hz
    Speed
    1800 rpm
    Emissions/Fuel Strategy
    Low Fuel, Tier 2 Nonroad Stds
    Duty Cycle
    Standby, Mission Critical, Prime, Continuous
  • Engine Specifications

  • Engine Model
    C32 TA, V-12, 4-Stroke Water-Cooled Diesel
    Compression Ratio
    15.0:1
    Aspiration
    TA
    Governor Type
    Adem™A4
    Fuel System
    MEUI
    Bore
    5.71in
    Displacement
    1958.86in³
    Stroke
    6.38in
    Fuel System
    6.38in
  • Generator Set Dimensions

  • Length - Minimum
    164in
    Height - Maximum
    86.4in
    Width - Minimum
    66.3in
    Length - Maximum
    172.7in
    Height - Minimum
    85.1in
    Width - Maximum
    87.7in
    Dry Weight - Genset (minimum)
    14700lb
    Dry Weight - Genset (maximum)
    16755lb

Equipment

  • Air Inlet System
    • Single element canister type with service indicator
  • Control Panel
    • Warning Shutdowns
    • EMCP 4.2B
    • Digital Indicators
    • Communications
    • Control Features
    • Programmable Protective Relaying Functions
  • Cooling System
    • Caterpillar Extended Life Coolant
    • ATAAC
    • Coolant drain line with valve
    • Low coolant level sensor
    • Fan and belt guards
    • Radiator fan and fan drive
  • Exhaust System
    • 203 mm (8 in) ID round flanged outlet
    • Exhaust manifold - Dry
  • Fuel System
    • Fuel cooler
    • Fuel priming pump
    • Secondary fuel filter
    • Primary fuel filter with water separator
  • General
    • RH Service
    • Caterpillar Yellow with high gloss black rails & radiator
    • SAE Standard Rotation
    • Flywheel and flywheel housing-SAE
  • Generators And Attachments
    • Class H temperature rise at 40C ambient
    • 3 Phase brushless
    • Permanent magnet
    • Winding temperature detectors
    • Integrated voltage regulator (IVR)
    • Reactive droop
    • IEC standard hole pattern
    • NEMA Class H insulation
    • Busbar connections, top center mounted, top cable entry
    • Salient pole
    • 6 Lead
    • Internal excitation
  • Governing System
    • ADEM(tm) A4
  • Lube System
    • Gear type lube oil pump
    • Oil drain lines and valve
    • Fumes disposal
    • Lubricating oil
    • Integral lube oil cooler
    • Oil filter, filler and dipstick
  • Mounting System
    • Rubber anti-vibration mounts
    • Rails - engine /generator / radiator mounting
  • Power Termination
    • Busbar
  • Starting And Charging
    • 45 Amp charging alternator
    • 24 Volt electric starting motor
    • Battery disconnect switch
    • Battery, rack and cables
  • Air Inlet System
    • Standard air cleaner
    • Heavy duty air cleaner
    • Dual element air cleaner
  • Circuit Breakers
    • Shrouds
    • 1600, 2000, 2500 and 3200 Amp, 3 Pole, IEC-Rated circuit breakers
    • Center posts busbars
    • Enclosures - Control packaging
    • 400, 800, 1200, 1600, 2000, 2500 and 3000 Amp, 3 Pole, UL-100% Rated circuit breakers
    • Circuit breaker wiring groups
    • Power connection covers
    • Cable supports
    • 800, 1600, 2000, 2500 and 3200 Amp, 4 Pole, IEC-Rated circuit breakers
  • Control Panels
    • EMCP 4.3, EMCP 4.4
  • Cooling System
    • High Ambient radiator
    • Extended life coolant
    • Standard radiator
    • Radiator duct flange
    • Certified radiator
  • Enclosures
    • Premium sound attenuated enclosure
    • Cold weather bundle
    • Color options
    • DC lighting package
    • Sound attenuated enclosure
    • AC panel, outlets and lights
    • Panel bracket
    • Enclosure Fuel Tank Options
    • Enclosure louvers - fixed and motorized
  • Exhaust System
    • Elbow mounting kit
    • Mufflers
    • Guard and Shield System
    • Flange and exhaust expanders
    • Flexible fittings
    • All C32 engines have 203 mm (8 in) exhaust outlets
    • Flanges
    • Exhaust through wall kit
  • General
    • US aid emblem
    • Special paint
  • Generator And Attachments
    • Medium Voltage Optional Generators
    • Low Voltage Optional Generators
  • Lube System
    • Oil level regulator
    • Oil pan
    • Prelube manual sump pump
  • Mounting System
    • Spring type vibration isolator
    • IBC vibration isolators
    • Mounting base types
    • Standard package isolators
  • Power Connections
    • Center post busbar
    • Low voltage connection cables
    • Neutral grounding connection
  • Power Termination
    • Circuit breakers, UL listed
    • Circuit breakers, IEC compliant
  • Special Tests / Reports
    • Standard engine test
    • IBC seismic certifications
    • PGS test report @ 1.0 power factor
    • Custom genset TVA report
    • Generator test report
    • Standard genset Torsional Vibration Analysis (TVA) report
    • PGS test report @ 0.8 power factor
    • CSA test and certification
    • OSHPD seismic certifications
  • Starting / Charging
    • 10 Amp enclosure battery charger
    • 35 Amp battery charger
    • Space heater
    • Jacket water heater
    • Electric starting motor - Standard / Heavy duty
    • Heavy-duty starting system
    • 10 Amp battery charger
    • 20 Amp battery charger

Request a Quote

Find a Boyd CAT
Location or Rep Near You