Diesel Generator Sets:

C2.2 Generator Set

Fuel System
3.9 in
Height - Maximum
43.9 in
Length - Maximum
59.1 in
Width - Maximum
24.4 in

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.



Product Specs

  • Engine Specifications

  • Fuel System
    3.9in
    Engine Model
    Cat® C2.2, In-line 4, 4-cycle diesel
    Compression Ratio
    22.5:1
    Governor Type
    Mechanical
    Fuel System
    Indirect Injection
    Bore
    3.3in
    Displacement
    135.2in³
    Stroke
    3.9in
    Aspiration
    Naturally Aspirated
  • Generator Set Dimensions

  • Height - Maximum
    43.9in
    Length - Maximum
    59.1in
    Width - Maximum
    24.4in
  • Generator Set Specifications

  • Minimum Rating
    13.0 kVA
    Maximum Rating
    22.0 kVA
    Emissions/Fuel Strategy
    R96/EUIIIa Equivalent
    Voltage
    110 to 415 Volts
    Frequency
    50 Hz
    Speed
    1500 rpm
    Duty Cycle
    Standby, Prime

Equipment

  • Air Inlet System
    • Air cleaner; light duty with disposable element
    • Air cleaner; light duty with disposable element
  • Control Panel
    • EMCP 4.1
    • EMCP4.1 control panel
  • Cooling System
    • Caterpillar extended life coolant
    • Fan drive, battery charging alternator drive
    • Radiator and cooling fan with guards
    • Coolant drain line with valve
    • Radiator and cooling fan with guards
  • Exhaust System
    • Stub pipe, gaskets, raincap & SAE exhaust flange for customer use; shipped loose
    • Stub pipe, gaskets, raincap & SAE exhaust flange for customer use; shipped loose
  • Fuel System
    • Standard open set fuel tank / base supplied
    • Base, formed steel with single wall integral 8-hour fuel tank
    • Standard open set fuel tank / base supplied
    • Base, formed steel with single wall integral 8-hour fuel tank
  • Generators And Generator Attachments
    • Segregated low voltage (AC/DC) wiring panel
    • Circuit breaker, IEC, 3 pole, mounted in tower panel
    • Voltage regulator (single phase sensing)
    • Tower panel, IP22, bottom cable entry
    • 12 leads
    • IP23 Protection
    • 12 leads
    • Tower panel, IP22, bottom cable entry
    • Segregated low voltage (AC/DC) wiring panel
    • IP23 Protection
  • Governing System
    • Mechanical governing system
    • Mechancial governing system
  • Lube System
    • Oil drain line with valve
    • Lubricating oil
    • Lubricating oil
    • Oil drain line with valve
  • Mounting System
    • Captive linear vibration isolators between base and engine-generator
    • Includes lifting provisions and termination points for coolant
    • includes lifting provisions and termination points for coolant
    • Captive linear vibration isolators between base and engine-generator
  • Starting / Charging System
    • 12 Volt battery with rack and cables
    • 12V battery with rack and cables
  • General
    • Engine and alternator pre-paint, Caterpillar yellow
  • Alternator Options
    • Coastal insulation protection
  • Certificates
    • European upgrade to STD set for CE certificate
    • Global certification for CIS
  • Circuit Breakers
    • 4 Pole circuit breaker
    • Pad-locable breaker device
  • Control Panel Options
    • Battery charger
    • Volt free contacts for genset running
    • Volt free contacts for common alarm
    • EMCP 4.2
    • Emergency stop with key
  • Cooling System
    • Coolant heater
  • Enclosures
    • Sound attenuated enclosure (GALV)
    • Single point lift for enclosure
  • Fuel System
    • Low fuel level alarm
  • Mounting Options
    • Industrial silencer removal
    • Silencer installation kit
    • Battery removal
  • Special Test And Inspection
    • PGS test report @ 1.0 power factor
  • General
    • Packing Case - compact set
    • Radiator Stone Guard
    • Packing case - canopied set

Request a Quote