- Bore
- 8.89 in
- Displacement
- 5155.88 in³
- Stroke
- 8.66 in
- Compression Ratio 50 Hz
- 16:7:1
Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
Product Specs
-
Engine Specifications
- Bore
- 8.89in
- Displacement
- 5155.88in³
- Stroke
- 8.66in
- Compression Ratio 50 Hz
- 16:7:1
- Compression Ratio 60 Hz
- 15:3:1
- Aspiration
- Turbo Aftercooled
- Fuel System
- Common Rail
- Engine Model
- C175-16 SCAC, V-16, 4-Stroke Water-Cooled Diesel
- Governor Type
- ADEM™ A4
- Compression Ratio
- 16:07:01
- Compression Ratio 50 Hz
- 16:07:01
- Compression Ratio 60 Hz
- 15:03:01
- Aspiration
- Turbo Aftercooled
- Fuel System
- EUI
- Bore
- 6.89in
- Displacement
- 5155.88in³
- Stroke
- 8.66in
-
Generator Set Specifications
- Minimum Rating
- 2500 ekW
- Maximum Rating
- 3100 ekW
- Voltage
- 480 to 13800 Volts
- Frequency
- 60 Hz
- Speed
- 1800 rpm
- Emissions/Fuel Strategy
- U.S. EPA Certified
- Duty Cycle
- Standby, Mission Critical, Prime, Continuous
-
Generator Set Dimensions
- Length - Minimum
- 242.77in
- Width - Minimum
- 83.1in
- Height - Minimum
- 87in
- Dry Weight - Genset (minimum)
- 42750lb
- Dry Weight - Genset (maximum)
- 45114lb
- Height - Maximum
- 142.3in
- Length - Maximum
- 312.2in
- Width - Maximum
- 123in
Equipment
-
- Control Panel
-
- - Warning/shutdown with common LED indication of shutdowns with indicating lights for:
- - Speed adjust
- Environmental sealed front face
- - Overspeed
- Lamp test
- - Emergency stop
- Generator mounted - rear facing
- - Volts (L-L & L-N)
- - Amps (per phase & average)
- - Auto / start / stop control
- Auto / start / stop control
- 24 Volt DC operation
- - Low oil pressure
- - Overcurrent (50/51)
- Local annunciator option
- - High coolant temperature.
- Overspeed
- - Generator phase sequence
- - Low coolant temperature
- 12 Programmable digital inputs
- kW (per phase, average & percent)
- - Emergency stop
- True RMS AC metering, 3-phase, +/-0.25% accuracy
- - Accessory module data link
- DC volts
- Low coolant level Over / Under voltage (27/59)
- - Low coolant level
- Controls:
- - Operating hours
- Amps (per phase & average)
- - coolant temperature
- - DC volts
- kVAr (per phase, average & percent)
- - kVA (per phase, average & percent)
- - Over / Under voltage (27/59)
- - Engine cool-down timer
- Failure to start (overcrank)
- - RPM
- - kVAr-hr (total)
- Low coolant level (requires optional coolant sensor)
- 4 Programmable relay outputs (Form A)
- Power Factor (per phase & average)
- Reverse reactive power (kVAr) (32RV)
- Emergency stop button
- - Frequency (Hz)
- Over / Under frequency (81 o/u)
- Volts (L-L & L-N)
- Warning / Shutdown with common LED indication of shutdowns with indicating lights for:
- - Power Factor (per phase & average)
- 2 Programmable digital outputs
- - alarm acknowledge
- - Customer data link (Modbus RTU)
- - Environmental sealed front face
- - Text alarm/event descriptions
- Digital indication for:
- Engine cool-down timer
- 6 Programmable digital inputs
- - Failure to start (overcrank)
- Customer data link (Modbus RTU)
- - Engine cycle crank
- 2 Programmable PWM outputs
- - Overspeed
- kVAr-hr (total)
- Low oil pressure
- - Over / Under frequency (81 o/u)
- Accessory module data link
- Low coolant temperature
- 16 Programmable digital outputs
- - kVAr (per phase, average & percent)
- kVA (per phase, average & percent)
- - kW (per phase, average & percent)
- Serial annunciator module data link
- EMCP 4.2B
- 2 Programmable relay outputs (Form C)
- Coolant temperature
- - kW-hr (total)
- Operating hours
- - Reverse reactive power (kVAr) (32RV)
- Programmable protective relaying functions:
- RPM
- - Lamp test
- 3 Programmable analog outputs
- Overcurrent (50/51)
- Alarm acknowledge
- - High coolant temperature
- - Reverse power (kW) (32)
- kW-hr (total)
- High coolant temperature
- - Failure to start (overcrank)
- Communications
- - Low coolant level (requires optional coolant sensor)
- Engine cycle crank
- EMCP 4.2B controller including:
- Reverse power (kW) (32)
- - True RMS AC metering, 3-phase, +/-0.25% accuracy
- Frequency (Hz)
- - 24 Volt DC operation
- Text alarm / event descriptions
- 3 Programmable analog inputs
- Speed adjust
- - Low oil pressure
-
- Cooling System
-
- Radiator group shipped loose
- Fan and belt guards
- SCAC cooling
- Coolant sensor - (2 x shipped loose: 1/4-18 and 1/2-14 NPTF)
- Coolant drain line and valves
-
- Exhaust System
-
- CEM dosing module features:
- Insulated CEM
- DEF filter
- CEM dosing module
- Harness from dosing module to CEM
- Air filter
- Anti-freeze protection
- 120 VAC
- Dry exhaust manifold
- Flanged faced outlets at CEM in (21.2") and out (25")
- Air and heated DEF lines from dosing module to CEM
-
- Fuel System
-
- Secondary / tertiary fuel filters
- Primary fuel filter water / fuel water separator
- 3 Filters, shipped loose - can be mounted on frame rails (Requires dealer provided flex)
- 10 Micron spin on type
- 3 Filters, engine mounted
- 4 Micron Spin On Type
- 10 Micron spin on type
-
- Generator And Attachments
-
- Caterpillar's digital voltage regulator (CDVR) includes:
- Permanent magnet
- (MV) Busbar connections, right side extension box, bottom cable entry: - 60 Hz models: NEMA standard hole pattern
- NEMA Class H insulation, Class F temperature rise at 40C ambient (105C prime / 130C standby)
- RFI suppression
- 3000 Frame generators (MV/HV)
- 6 Lead
- Reactive droop capability
- Class H temperature rise at 40C ambient (125C prime / 150C standby)
- Form wound
- 3 Phase voltage sensing
- KVAR / PF modes
- Right side extension box, bottom cable entry
- 3 Phase brushless, salient pole
- Anti condensation space heater
- IEC platinum stator RTDs (.00385 temperature coefficient)
- Exciter diode monitor
- 1800 Frame generators (LV/MV)
- Min / Max exciter limiter
- (LV) Busbar connections, top / center mounted, top cable entry 60 Hz models: NEMA standard hole pattern
- NEMA Class H insulation
-
- Governing System
-
- ADEM A4
- Redundant shutdown (Overspeed protection through a duplicate speed sensing system)
-
- Lube System
-
- Oil filter, filler and dipstick
- Gear type lube oil pump
- Integral lube oil cooler
- Lubricating oil
- Prelube - required with prime and continuous; optional with standby
- Oil drain lines and valve
- Fumes disposal
-
- Mounting System
-
- Batteries and battery rack w/cables
- Battery disconnect switch
- Rubber anti-vibration mounts (shipped loose)
- Dual 24-volt electric starting motors
- Rails - Engine / Generator
-
- Service Instructions
-
- Two PM Inspections
-
- General
-
- * For HV applications, customer to provide 120V secondary sensing, 5A secondary current sensing and harness between package and EMCP4.3 (drawing provided). CDVR is installed in wall mount.
- Paint - Caterpillar yellow with high gloss black rails & radiator
- *For HV EMCP4.3 control panel: Includes wall mount control panel, shipped loose, for customer mounting and 7.5 meter interconnect harness.
- RH Service (except oil filter service 60 Hz models: left hand service
- SAE standard rotation
- Flywheel and flywheel housing-SAE No. 00
-
- Air Inlet System
-
- Air cleaner; 4 x single element canister with service indicator(s).
- Single stage air cleaner
-
- Air Inlet System
-
- Single stage air cleaner
-
- Control Panels
-
- Customer interface options
- Customer AC-DC connection mounting location - LV / MV
- EMCP 4.3 and EMCP 4.4 (requires 1800 frame low voltage package)s
- Remote speed adjust
- Modbus monitoring of packages
- Vandal proof panel door
- E-Stop - Only for use with 3000 frame generators and EMCP4.3
- Generator temperature monitoring
- EMCP mounting location - LV / MV (requires 1800 frame generator)
- Load share module
- Load share governor / auxiliary plate and auxiliary box (LV)
- Annunciator modules
-
- Cooling System
-
- SCAC circuits
- Package mounted radiator
- Remote radiators
- Fuel cooler
-
- Exhaust
-
- Exhaust collectors / manifold
-
- Fuel System
-
- Primary fuel filter
-
- General
-
- Paint - colors (other than Caterpillar yellow) or high performance paints
- US aid emblem
-
- Generator And Attachments
-
- Differential current transformers (DCT): - 5, 9 and 15 kV class DCTs
- Space heater kit
- 480 Volts, Generators (MV) 60 Hz, 3 phase, 1800 rpm, FW, PM, 6 leads, pitch = 0.6667 -- 1800, 3000 frame
- Thermostat for space heater
- 480 Volts, Generators (LV) 60 Hz, 3 phase, 1800 rpm, FW, PM, 6 leads, pitch = 0.6667 - 1800 frame
-
- Instrumentation
-
- Harness - ECM interconnect
- Pyrometer and thermocouples
-
- Lube System
-
- Electric prelube pump
- Lubricating oil
- Standard sump oil pan
- Oil pan drain valve
- Oil filters
- Lube oil heater
-
- Crankcase Systems
-
- Explosion relief valves
-
- Mounting System
-
- Spring-type linear vibration isolators
- Rubber anti-vibration mounts
- IBC vibration isolators - shipped loose
-
- Power Connections
-
- 5000 Amp, 3 Pole, UL-100% rated circuit breakers
- Side / Rear monted busbars (LV)
- MV Power Connection Options: 1800 Frame generator side / rear mounted busbars - Left hand MV nema busbar - Right hand MV nema busbar
- 5000 Amp, 3 Pole, IEC-rated circuit breakers
- Center post busbars (LV) connections
- Neutral ground - (MV)
- Cable entry options (LV)
- Masterpack breaker connections
- Circuit Breaker Harness
- Power connection covers
- Cable entry options - 1800 frame (MV)
- Control packaging (LV) - Enclosures
- Optional package mounted circuit breakers (LV)
- 4000 Amp, 3 Pole, UL-100% rated circuit breakers
- 4000 Amp, 3 Pole, IEC-Rated circuit breakers
-
- Service Tools - Barring Groups
-
- Control GP-airpowered group
- Engine group
- Group manual
- Engine air powered
-
- Special Tests / Reports
-
- Standard genset torsional vibration analysis (TVA) report
- Custom genset TVA report
- Standard engine test charge
- PGS test report @ 0.8 power factor
- Generator test report
- PGS test report @ 1.0 power factor
- Fuel consumption test
-
- Starting/charging
-
- Heavy duty battery set with rack
- Jacket water heater wiring groups
- Jacket water heaters
- 24 Volt power distribution box
- 35 and 50 Amp battery chargers
- Covers - starter locations
- 24 Volt electric starting motor
- Air starting motor
- 24 Volt battery set - dry