Diesel Generator Sets:

C13 Generator Set

Duty Cycle
Standby, Prime
Fuel System
6.18 in
Minimum Rating
320 ekW
Maximum Rating
400 ekW

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.



Product Specs

  • Generator Set Specifications

  • Duty Cycle
    Standby, Prime
    Minimum Rating
    320 ekW
    Maximum Rating
    400 ekW
    Voltage
    380 to 415 Volts
    Frequency
    60 Hz
    Speed
    1800 rpm
    Emissions/Fuel Strategy
    Low Fuel Consumption
  • Engine Specifications

  • Fuel System
    6.18in
    Engine Model
    C13 ATAAC, I-6, 4-Stroke Water-Cooled Diesel
    Compression Ratio
    16.3:1
    Aspiration
    Air to Air Aftercooled
    Governor Type
    Adem™A4
    Fuel System
    MEUI
    Bore
    5.12in
    Displacement
    762.8in³
    Stroke
    6.18in
  • Generator Set Dimensions

  • Height - Maximum
    84in
    Length - Maximum
    186.7in
    Width - Maximum
    79.3in

Equipment

  • Air Inlet System
    • Aftercooler core
    • Air cleaner; light duty with disposable paper filter
    • Turbocharger
  • Control Panel
    • EMCP 4.2
  • Cooling System
    • Caterpillar Extended Life Coolant
    • Coolant drain line with valve
    • Fan drive, battery charging alternator drive
    • Radiator and cooling fan with guard
  • Exhaust System
    • Stainless steel exhaust flex, gaskets, raincap & SAE exhaust flange for customer use; shipped loose
  • Fuel System
    • Base, formed steel with single wall integral 8-hour fuel tank
    • Standard open set fuel tank / base supplied
  • Generator And Attachments
    • Segregated low voltage (AC/DC) wiring panel
    • Power center, IP22
    • Integrated Voltage Regulator
    • Mandatory Option circuit breaker, IEC, 3 pole, mounted in power centre
    • A frame generator - IP21 Protection
    • Optional LC frame generator - IP23 Protection
  • Governing System
    • Cat Electronic Governor (ADEM A4)
  • Packaged Generator Set
    • Service indicator
    • Radiator package mounted
    • Low coolant level sensor
    • Coolant drain line with valve
    • Coolant level sight gauge
    • Disposable Air filter
  • Lube System
    • Lubricating oil
    • Oil drain valves
    • Oil Cooler
  • Mounting System
    • Captive linear vibration isolators between base and engine-generator
    • Includes lifting provisions and termination points for coolant and lube oil drain lines
  • Starting / Charging System
    • 24V battery with rack and cables
  • General
    • Engine and alternator pre-paint, Caterpillar yellow
  • European Certificates
    • EU certificate of conformance
    • Global certificate for CIS
  • Air Inlet System
    • Single element air cleaner
    • Dual element air cleaner
  • Circuit Breakers
    • 4 Pole (IEC-100% rated) circuit breaker
    • Circuit breaker (IEC) auxiliary contacts
    • 4 Pole (IEC-100% rated) circuit breaker - Motorised
    • Pad-lockable circuit breaker device
    • Power terminal strip
    • Shunt trip for IEC circuit breaker
    • 3 Pole (IEC-100% rated) circuit breaker
    • 3 Pole (IEC-100% rated) circuit breaker - Motorised
  • Control Panels
    • EMCP 4.3, EMCP 4.4
    • Local alarm modules: Local annunciator
    • Volt free contacts
    • Control panel protective devices: Earth fault relay ; Earth leakage ground fault ; Overload shutdown via breaker ; low fuel level alarm ; Low fuel level shutdown ; High fuel level alarm ; Fuel level sensor
    • Remote annunciator modules
  • Cooling System
    • Stone guards
    • Radiator duct flange
    • Low coolant temperature alarm
  • Enclosures
    • Sound attenuated enclosures
    • High ambient sound attenuated enclosures
  • Exhaust System
    • 6 and 8 inch elbow kit
    • Flexible 8 inch exhaust fittings
    • 6 and 8 inch flange GP
    • Mufflers - End in / End out
    • 10, 25 and 35 dBA attenuation
  • Fuel System
    • Manual fuel transfer pump
    • Integral dual wall fuel tank base
    • Fuel transfer system controls
  • Generator And Attachments
    • Permanent magnet generator
    • LC frame generator
    • LC CIP generator
    • A frame CIP generator
    • A frame oversize generator
    • Ingress protection
    • Space heaters
  • Lube System
    • Manual sump pump
  • Mounting System
    • Narrow skid base
  • Starting / Charging System
    • 5 Amp single battery charger
    • Jacket water heater
    • Battery disconnect switch

Request a Quote

Find a Boyd CAT