Diesel Generator Sets:

3516C Generator Set

Height - Maximum
118.5 in
Length - Maximum
295.1 in
Width - Maximum
101.2 in
Minimum Rating
1650 ekW

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.



Product Specs

  • Generator Set Dimensions

  • Height - Maximum
    118.5in
    Length - Maximum
    295.1in
    Width - Maximum
    101.2in
    Length - Minimum
    284.6in
    Width - Minimum
    93.7in
    Height - Minimum
    116.5in
    Dry Weight - Genset (minimum)
    35880lb
    Dry Weight - Genset (maximum)
    38780lb
  • Generator Set Specifications

  • Minimum Rating
    1650 ekW
    Maximum Rating
    2500 ekW
    Voltage
    380 to 13800 Volts
    Frequency
    60 Hz
    Speed
    1800 rpm
    Emissions/Fuel Strategy
    U.S. EPA Cert., Tier 2
    Duty Cycle
    Standby, Mission Critical, Prime, Continuous
  • Engine Specifications

  • Engine Model
    3516C, ATAAC, V-16,4-Stroke Water-Cooled Diesel
    Compression Ratio
    14.7:1
    Aspiration
    TA
    Governor Type
    Adem™3
    Fuel System
    Electronic unit injection
    Bore
    6.69in
    Stroke - HD
    8.46in
    Stroke - Standard
    7.48in
    Stroke
    7.48in
    Displacement
    4764.73in
    Fuel System
    7.48in

Equipment

  • Air Inlet System
    • Air Cleaner; single element canister type
  • Cooling
    • Package mounted radiator
  • Exhaust
    • Exhaust flange outlet
  • Control Panels
    • Communications:
    • Reverse reactive power (kVAr) (32RV)
    • Customer data link (Modbus RTU)
    • Generator mounted - rear facing
    • 1 Programmable digital outputs
    • Auto / start / stop control -
    • Serial annunciator module data link
    • Engine cool-down timer
    • 24 Volt DC operation
    • Controls:
    • Generator set packages include Caterpillar' s Voltage Regulator. IVR includes reactive droop capability, 3-phase voltage sensing, KVAR / PF modes, RFI suppression, min / max exciter. Limiter and exciter diode monitor
    • Alarm acknowledge
    • Cat connect
    • Engine cycle crank
    • Text alarm / event descriptions
    • Overcurrent (50 / 51)
    • Accessory module data link
    • EMCP 4.2B
    • 1 Programmable relay outputs (Form C)
    • Emergency stop pushbutton
    • Speed adjust -
    • 4 Programmable relay outputs (Form A)
    • Number of I/O varies on options selected:
    • 6 Customer programmable digital inputs
    • Environmental sealed front face
    • Load histogram feature
    • Lamp test
    • PLC functionality
    • Customizable screens -0 True RMS AC metering, 3-phase, +/-2% accuracy
    • Digital indication for:
    • Operating hours
    • RPM
    • DC volts
    • Frequency (Hz)
    • Coolant temperature
    • Volts (L-L & L-N)
    • Oil pressure (psi, kPa or bar)
    • Amps (per phase & average)
    • kVAr (per phase, average & percent
    • kVA (per phase, average & percent)
    • kW (per phase, average & percent)
    • Power Factor (per phase & average)
    • kW-hr (total)
    • kVAr-hr (total)
    • High coolant temperature
    • Overspeed
    • Failure to start (overcrank)
    • Warning / shutdown with common LED indication of shutdowns for:
    • Emergency stop
    • Low oil pressure
    • Low coolant level -
    • Low coolant temperature
    • Programmable protective relaying functions:
    • Over / under Frequency (81 o/u)
    • Generator phase sequence
    • Over / under voltage (27 / 59)
    • Reverse power (kW) (32)
  • Fuel
    • Primary fuel filter with integral water separator
  • Generator
    • Matched to the performance and output characteristics of Cat engines
    • IP23 Protection
  • Power Termination
    • Busbar
  • Control Panel
    • EMCP 4 Genset Controller
  • Cooling System
    • Certified standard PGS provided
    • ATAAC - 3516E Package Radiators shipped installed
  • Exhaust System
    • Flanged faced outlet(s)
    • Dry exhaust manifold
  • Fuel System
    • Flexible fuel lines - shipped loose
    • Fuel cooler; not included with packages without radiator
    • Secondary fuel filters
    • Fuel priming pump
  • General
    • Caterpillar yellow with high gloss black rails and radiator
    • Right hand servicing
    • Flywheel and flywheel housing - SAE No. 00
    • Paint - Caterpillar Yellow except rails and radiators gloss black
    • SAE Standard rotation
  • Generator And Attachments
    • Busbar connections, top center mounted, top cable entry
    • Class H temperature rise at 40C ambient (125C prime / 150C standby)
    • Low Voltage:
    • NEMA standard hole pattern
    • Medium Voltage:
    • Anti condensation space heater
    • 6 Lead
    • Random wound
    • Form wound
    • NEMA Class H insulation, Class H temperature rise at 40C ambient (125C prime / 150C standby)
    • Permanent magnet
    • Class H insulation, Class F temperature rise at 40C ambient (105C prime/130C standby)
    • Internal excitation
    • 3 Phase brushless, salient pole
    • High voltage:
    • Winding temperature detectors
    • Busbar connections, right side extension box, bottom cable entry
  • Governing System
    • ADEM A3
  • Literature
    • English
  • Lubrication System
    • Lubricating oil
    • Fumes disposal
    • Integral lube oil cool
    • Oil drain lines and valve
    • Oil filter, filler and dipstick
    • Gear type lube oil pump
  • Mounting System
    • Anti-vibration mounts (shipped loose)
    • Rubber anti-vibration mounts (shipped loose)
    • Rails - engine/generator/radiator mounting
  • Starting System
    • Battery disconnect switch
    • 45 Amp charging alternator
    • 24 Volt electric starting motor
    • Battery and battery rack w/cables
  • Control System
    • EMCP4.3, EMCP 4.4
  • Exhaust
    • Exhaust mufflers
  • Air Inlet System
    • Single element filter
    • Dual element air cleaner
  • Generator
    • Excitation: [ ] Permanent Magnet Excited (PM) [ ] Internally Excited (IE)
    • Oversize and premium generators
    • Anti-condensation heater
  • Cooling System
    • Coolant
    • Standard ambient ATAAC radiators
    • Optional installed radiators
    • Optional installed ATAAC radiators
    • Standard ambient radiators
    • Water level switch gauges
  • Power Termination
    • Circuit breakers, UL listed
    • Circuit breakers, IEC compliant
  • Crankcase System
    • Explosion relief valves
    • Ventilation system
    • No explosion relief valves
  • Control Panels
    • Load share module
    • Digital I/O module
    • Generator temperature monitoring & protection
    • Remote monitoring software
  • Mounting
    • Rubber anti-vibration mounts
    • IBC isolators
  • Exhaust System
    • Y-Adapters
    • Flexible fittings
    • Exhaust offset
    • Tier 4 clean emissions module
    • Elbows
    • Flange and exhaust expanders
    • Tier 4 clean emission MOD Kits
    • Tier 4 dosing cabinet
    • Flanges
    • Mufflers
    • Clean emission parts
  • Starting/charging
    • Oversize batteries
    • Battery chargers
    • Charging alternator
    • Air starting motor with control and silencer
    • Heavy-duty starting system
  • Fuel System
    • Primary Fuel Filter
  • General
    • The following options are based on regional and product configuration:
    • UL 2200 package
    • CSA Certification
    • EEC Declaration of Conformity
    • Special paint (Colors other than Caterpillar yellow or high performance paints)
    • Integral & sub-base fuel tanks
    • US aid emblem
    • Enclosures: sound attenuated, weather protective
    • Automatic transfer switches (ATS)
    • Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
    • EU Certificate of Conformance (CE)
    • Integral & sub-base UL listed dual wall fuel tanks
  • Generators And Attachments
    • High voltage: 12470, 13200, 13800 volts, 3 phase 1800 rpm,FW, PM, No. of Leads = 6, Pitch = .6667: 2700, 3000 Frame
    • High voltage: 6300, 6600, 6900 volts, 3 phase 1800 rpm, FW, PM, No. of Leads = 6, Pitch = .6667: 2700, 3000 Frame
    • Thermostate for space heater
    • Low / Medium voltage: 380, 440, 480, 600 volts, 3 phase 1800 rpm. RW, IE, No. of Leads = 6, Pitch = .6667: 1600 Frame
    • Low / Medium voltage: 380, 416, 440, 480, 600, 2400, 4160 Volts, 3 Phase 1800 RPM, FW, PM, No. of Leads = 6, Pitch = .6667: 1600, 1800 Frame
    • Differential current transformers (DCT) 8.7 kV and 15 kV classes
    • Generator conversion
    • Space heater kits
    • Alternator air cleaner
  • Instrumentation
    • Pyrometer and thermocouples
  • Lubrication System
    • Oil level regulator
    • Lube oil in standard sump
    • Prelube pumps
  • Mounting System
    • Puck style low efficiency isolators
    • Spring type vibration isolators
    • IBC vibration isolators
  • Power Connections
    • Ground cables between generator and terminal box
    • Neutral ground connections
    • Left side power connections
    • Center post busbar
    • Right side power connections
    • 2700 Frame, four lead, four terminal
    • Rear power connections
    • Low voltage circuit breakers
  • Special Tests / Reports
    • IBC certification
    • Fuel consumption test
    • Generator test report
    • PGS test report @ 1.0 power factor
    • Torsional vibration analysis reports
    • OSHPD certification
    • Generator set fuel consumption test
    • PGS test report @ 0.8 power factor
    • Standard engine test charge
    • Canadian Standards Association certification
  • Starting And Charging
    • Air pressure regulator
    • Starter cover
    • Air starting motors
    • 10, 20, 35 and 50 amp battery chargers
    • Electric starting motors
    • Jacket water heaters
    • 24 Volt battery set - Dry
    • Engine barring device
  • Extended Service Coverage
    • Platinum, Gold and Silver coverage

Request a Quote

Find a Boyd CAT
Location or Rep Near You