Diesel Generator Sets:
3512B (50 Hz) Generator Set
Contact Us About This Product
Click a link to download the document:
- Bore
- 6.69 in
- Displacement (HD)
- 3573.55 in3
- Stroke (HD)
- 8.46 in
- Aspiration
- TA
Caterpillar is leading the power generation market with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
Product Specs
-
Engine Specifications
- Bore
- 6.69in
- Displacement (HD)
- 3573.55in3
- Stroke (HD)
- 8.46in
- Aspiration
- TA
- Fuel System
- Electronic Unit Injection
- Engine Model
- 3512B TA, V-12, 4-Stroke Water-Cooled Diesel
- Displacement - Std
- 3161.03in³
- Stroke - Standard
- 7.48in
- Compression Ratio
- 14.0:1 Std 15.5:1 HD
- Governor Type
- Adem™3
- Stroke
- 7.48in
- Displacement
- 3161.03in
- Aspiration
- TA
- Fuel System
- Electronic Unit Injection
- Bore
- 6.69in
- Displacement - HD
- 3573.55in³
- Stroke - HD
- 8.46in
- Fuel System
- 7.48in
-
Generator Set Specifications
- Minimum Rating
- 1320 kVA
- Maximum Rating
- 1875 kVA
- Voltage
- 380 to 415 Volts
- Frequency
- 50 Hz
- Speed
- 1500 rpm
- Emissions/Fuel Strategy
- Low Fuel, Low Emissions
- Duty Cycle
- Standby, Mission Critical, Prime
-
Generator Set Dimensions
- Length - Minimum
- 206.6in
- Width - Minimum
- 77.8in
- Dry Weight - Genset (minimum)
- 25010lb
- Dry Weight - Genset (maximum)
- 26840lb
- Height - Maximum
- 93.2in
- Length - Maximum
- 215.3in
- Width - Maximum
- 90in
Equipment
-
- Air Inlet System
-
- Aingle element canister type air cleaner with service indicator
-
- Air Inlet
-
- Air Cleaner
-
- Cooling
-
- Package mounted radiator (except C175)
-
- Control Panel
-
- Emergency stop button
- Programmable protective relaying functions:
- Over / under voltage (27 / 59)
- kVAr (per phase, average & percent)
- kVA (per phase, average & percent)
- Engine cool-down timer
- Generator mounted - rear facing
- Overcurrent (50 / 51)
- Warning / shutdown with common LED indication of shutdowns for:
- Low coolant level
- DC volts
- Generator phase sequence
- Overspeed
- Frequency (Hz)
- Volts (L-L & L-N)
- Reverse reactive power (kVAr) (32RV)
- Text alarm / event descriptions
- 2 Programmable digital outputs
- RPM
- 2 Programmable relay outputs (Form C)
- Speed adjust
- Alarm acknowledge
- kVAr-hr (total)
- Digital indication for:
- Power Factor (per phase & average)
- Environmental sealed front face
- Controls:
- True RMS AC metering, 3 phase, +/-2% accuracy
- Low oil pressure
- kW (per phase, average & percent)
- Engine cycle crank
- Accessory module data link
- Coolant temperature
- EMCP 4.2
- 24 Volt DC operation
- Over / under frequency (81 o/u)
- Amps (per phase & average)
- 4 Programmable relay outputs (Form A)
- Reverse power (kW) (32)
- Operating hours
- Communications
- Oil pressure (psi, kPa or bar)
- Serial annunciator module data link
- kW-hr (total)
- 6 Programmable digital inputs
- High coolant temperature
- Failure to start (overcrank)
- Low coolant temperature
- Lamp test
- Emergency stop
- Auto / start / stop control
- Customer data link (Modbus RTU)
-
- Exhaust
-
- Exhaust flange outlet
-
- Fuel
-
- Secondary fuel filter
- Primary fuel filter with integral water separator
- Fuel priming pump
-
- Control System
-
- Engine cool-down timer.
- DC volts
- True RMS AC metering, 3-phase, +/-2% accuracy
- High coolant temperature
- Coolant temperature
- Auto/start/stop control
- Failure to start (overcrank)
- Communications
- Oil pressure
- Emergency stop
- EMCP4.2B
- Overspeed
- frequency (Hz)
- Volts (L-L & L-N)
- Engine cycle crank
- Warnings / Shutdown indicators
- Speed adjust
- Lamp test
- 24-volt DC operation
- RPM
- 4 programmable digital inputs
- Low coolant level
- Operating hours
- Alarm acknowledge
- Emergency stop pushbutton
- Low oil pressure
- Amps (per phase & average)
- 4 programmable digital outputs
- Digital indication for:
-
- Generator
-
- IP23 Protection
- Matched to the performance and output characteristics of Cat engines
-
- Power Termination
-
- Bus Bar
-
- Generator System
-
- Class H temperature rise at 40C ambient
- 3 phase brushless, salient pole
- 6 lead
- Winding temperature detectors
- NEMA Class H insulation
- Random wound
- Internal Excitation
- 3-phase voltage sensing
- Bus bar connections
- min/max exciter
- Caterpillar's Digital Voltage Regulator (CDVR)
- RFI suppression
-
- Literature
-
- English
-
- Cooling System
-
- Caterpillar extended life coolant. (Not included with packages without radiator, installed SF44CTS, shipped loose radiators or heat exchangers)
- JWAC
- Coolant level sensors. (Not included with packages without radiator)
- Coolant drain line with valve
- Radiator fan and fan drive
- Fan and belt guards
-
- Exhaust System
-
- Dry exhaust manifold
- Flanged faced outlet(s)
-
- Fuel System
-
- Fuel priming pump
- Secondary fuel filters
- Fuel cooler; not included with packages without radiator
- Flexible fuel lines - shipped loose
-
- Generators And Attachments
-
- Note: 1800 frames are form wound, permanent magnet, with winding temp detectors
- 3 Phase voltage sensing
- RFI suppression
- Class H temperature rise at 40C ambient (125C prime / 150C standby)
- Min / max exciter limiter
- Exciter diode monitor
- Busbar connections, top center mounted, top cable entry
- 3 Phase brushless, salient pole
- 50 Hz models: IEC standard hole pattern
- Caterpillar's Digital Voltage Regulator (CDVR) includes:
- Random wound
- Generator set packages include: Regulator (CDVR)
- Reactive droop capability
- 6 Leads
- KVAR / PF modes
- NEMA Class H insulation
- Winding temperature detectors
- Internal Excitation
- LV:
-
- Governing System
-
- Woodward 2301A isochronous governor
-
- Lube System
-
- Lubricating oil
- Gear type lube oil pump
- Integral lube oil cooler
- Oil filter, filler and dipstick
- Fumes disposal
- Oil drain lines and valve
-
- Mounting System
-
- Rails - engine / generator / radiator mounting
- Rubber anti-vibration mounts (shipped loose)
-
- Starting / Charging System
-
- Battery disconnect switch
- Battery and battery rack w/cables
- 24-volt electric starting motor
-
- General
-
- SAE standard rotation
- Flywheel and Flywheel housing-SAE No. 00
- RH Service
- Paint - Caterpillar yellow with high gloss black rails & radiator
-
- Air Inlet System
-
- Air Inlet protection
- Remote air inlet adaptors
- Dual element air cleaners
-
- Exhaust
-
- Exhaust mufflers
-
- Generator
-
- Anti-condensation heater
- Internal excitation (IE)
- Permanent magnet excitation (PMG)
- Oversize and premium generators
-
- Circuit Breakers
-
- Cable entry options
- 2000, 2500, 3200 and 4000 Amp, 4 pole, IEC rated circuit breakers
- Busbar connections
- Center posts busbars
- Controls packaging - Enclosures
- 2000, 2500, 3200 and 4000 Amp, 3 pole, IEC rated circuit breakers
- Optional busbar power connections
- EMAX breakers connections
- EMAX circuit breakers
- Breaker harnesses
-
- Power Termination
-
- Circuit breakers, UL listed
- Circuit breakers, IEC compliant
-
- Control Panels
-
- Annunciator modules
- Customer connection mounting locations
- Remote speed adjust
- Local PC monitoring
- Generator temperature monitoring
- Auxiliary boxes
- Governors
- Customer interface options
- EMCP 4.3, EMCP 4.4
- Ground (Automatically selected)
- Mounting group - External box clips
- Vandle proof panel door
-
- Mounting
-
- Rubber anti-vibration mounts
- IBC isolators
- Spring-type vibration isolator
-
- Starting/charging
-
- Oversize batteries
- Air starting motor with control and silencer
- Jacket water heater
- Heavy-duty starting system
- Charging alternator
- Battery chargers
-
- Cooling System
-
- Water level switch gauges
- Optional radiator arrangements
- Heat exchangers
-
- European Certifications
-
- European Union certification
- EU declaration of conformity
- European directive genset, DoI (Declaration of Incorporation)
- Eurasian conformity (EAC) mark
-
- Exhaust System
-
- Mufflers
- Muffler mounting kits
- Through-wall installation kit
- Flexible fittings
-
- Fuel System
-
- Primary fuel filter
-
- Generators And Attachments
-
- Generator conversion
- 1500 RPM, 380/400/415volts @ 50 Hz, 3 phase, random wound, permanent magnet, No. of leads = 6, pitch= 0.6667
- 1500 RPM, 380/400/415volts @ 50 Hz, 3 phase, form wound, permanent magnet, No. of leads = 6, pitch= 0.6667
- 1500 RPM, 380/400/415volts @ 50 Hz, 3 phase, random wound, internal excitation, No. of leads = 6, pitch= 0.6667
- Space heater
-
- Instrumentation
-
- Pyrometer and thermocouples
-
- Lube System
-
- Oil level Reg-1 shallow pan
- Electric prelube pumps
- Manual prelube sump pumps
-
- Mounting System
-
- IBC vibration isolators
- Spring-type vibration isolator
-
- Protection System
-
- Explosion relief valve
-
- Special Tests / Reports
-
- PGS test report @ 0.80 power factor
- Neutral ground-LV
- IBC seismic certifications
- PGS test report @ 1.0 power factor
- Neutral grounding connection
-
- Starting / Charging System
-
- Oversize battery set
- Jacket water heaters
- 10 Amp battery chargers
- Ether starting aid
- 24 Volt dual electric starting motor
- 20 Amp battery charger
-
- General
-
- Engine barring group