C1.5 Generator Set (Single Phase 1.0 pf)
Minimum Rating
10 ekW (10 kVA)
Maximum Rating
13 ekW (16.5 kVA)
Frequency
50 Hz or 60 Hz
Speed
1500 rpm (50Hz) or 1800 rpm (60 Hz)

Cat® C1.5 Diesel Marine Generator Set has single phase ratings of 50 Hertz at 10.0 ekW and 60 Hertz at 12.0 ekW that meet U.S. EPA Tier 3 and EU IW emission standards. The Cat® C1.5 also has three phase ratings of 50 Hertz at 11.0 ekW and 60 Hertz at 13.0 ekW that meet U.S. EPA Tier 3 and EU IW emissions standards. This generator set is available in 12 or 24 volt as an open gen set or as an enclosed package.



Product Specs

  • Generator Set Specifications

  • Minimum Rating
    10 ekW (10 kVA)
    Maximum Rating
    13 ekW (16.5 kVA)
    Frequency
    50 Hz or 60 Hz
    Speed
    1500 rpm (50Hz) or 1800 rpm (60 Hz)
    Minimum Rating
    10 ekW (10 kVA)
    Maximum Rating
    13 ekW (16.5 kVA)
    Frequency
    50 Hz or 60 Hz
    Speed
    1500 rpm (50Hz) or 1800 rpm (60 Hz)
    Emissions/Fuel Strategy
    60 Hz meets EPA Tier 3*, 50 Hz meets EU 97/68EC Stage II regulations
  • Generator Set Configurations

  • Emissions/Fuel Strategy
    60 Hz meets EPA Tier 3*, 50 Hz meets EU 97/68EC Stage II regulations
  • Engine Specifications

  • Engine Model
    C1.5, In-line 3, 4-Stroke-Cycle-Diesel
    Aspiration
    Naturally Aspirated
    Bore
    3.31in
    Stroke
    3.5in
    Displacement
    91.0in3
    Governor Type
    Electrical Isochronous
    Engine Model
    C1.5, In-line 3, 4-Stroke-Cycle-Diesel
    Aspiration
    Naturally Aspirated
    Bore
    3.31in
    Stroke
    3.5in
    Displacement
    91in³
    Governor Type
    Electrical Isochronous
  • Generator Set Dimensions

  • Weight
    319 kg/703 lbs (open), 368 kg/811 lbs (enclosed)
    Width
    21 in/533 mm (open), 24 in/608 mm (enclosed)
    Width
    21 in/533 mm (open), 24 in/608 mm (enclosed)
    Height
    27.5 in/699 mm (open), 28 in/710 mm (enclosed)
    Length
    37.4 in/962 mm (open), 40 in/1021 mm (enclosed)
    Weight
    319 kg/703 lbs (open), 368 kg/811 lbs (enclosed)
  • Generator Specifications

  • Frame Size
    1.5
    Excitation
    AREP
    Insulation
    Class H
    Voltage Regulation
    ±0.5%

Equipment

  • Air Inlet System
    • Air cleaner, single element canister type with rain cap (open generator set only)
  • Control System
    • Electronic isochronous governor
  • Cooling System
    • Belt-driven centrifugal jacket water pump
    • gear-driven seawater pump
    • heat exchanger with copper nickel tubes
    • expansion tank
  • Exhaust System
    • Watercooled exhaust manifold and elbow
  • Fuel System
    • Fuel filter — RH or LH service
    • fuel priming
    • fuel transfer pump
    • flexible fuel lines
  • Generator
    • Single Phase
  • Lube System
    • Lubricating oil
    • oil filter (RH)
    • dipstick (RH)
    • fumes disposal (closed system)
  • Mounting System
    • Anti-vibration mounts, connected to drip tray and steel base sitting on PVC foam sound-absorbent pad
  • Protection System
    • Electronic automatic safety shutdown for low oil pressure, high water temperature, high exhaust (wet exhaust only) temperature, and overspeed
  • Starting System
    • 12 or 24 volt electronic starting motor, 12 volt 55 amp alternator
  • General
    • Single-side service (RH), decals, literature