Land Electric-Drive Modules:

G3516B Land Electric-Drive Drilling Module

3516B Land Drilling Generator Sets
Minimum Rating
1320.0 ekW
Maximum Rating
1320.0 ekW
Emissions
Non-certified
Engine Control and Protection
ADEM A3

Oil and gas drilling is a complex task that requires specialized power generation equipment. Cat 3500 generator sets are specifically designed for drilling operations of electric AC rigs. They combine decades of field experience of the 3500 platform with technology in electronics to ensure highest performance, low emissions, and simplified operator interface.Cat engines are backed by the worldwide network of Cat dealers ready to support your operation with technical support, service, parts, and warranty.



Product Specs

  • Engine Specifications

  • Minimum Rating
    1320.0ekW
    Maximum Rating
    1320.0ekW
    Emissions
    Non-certified
    Engine Control and Protection
    ADEM A3
    Generator
    SR4B
    Aspiration
    Turbocharged-Aftercooled
    Bore
    6.69in
    Stroke
    7.48in
    Displacement
    4210.0in3
    Fuel System
    EUI
    Oil Change Interval
    500.0hr
    Weight
    41469.0lb
    Minimum Rating
    1320ekW
    Maximum Rating
    1320ekW
    Emissions
    Non-certified
    Aspiration
    Turbocharged-Aftercooled
    Bore
    6.69in
    Displacement
    4210in³
    Engine Control and Protection
    ADEM A3
    Fuel System
    EUI
    Generator
    SR4B
    Oil Change Interval
    500h
    Stroke
    7.48in
    Weight
    41469lb
    Voltage
    600
  • Capacity for Liquids

  • Lube Oil System (Refill)
    107.0gal
    Cooling System (Engine)
    61.5gal
    Cooling System - Engine
    61.5gal (US)
    Lube Oil System - Refill
    107gal (US)
  • Dimensions

  • Width
    93.9in
    Length
    310.0in
    Height
    99.2in
    Height
    99.2in
    Length
    310in
    Width
    93.9in

Equipment

  • Air Inlet System
    • Corrosion-resistant aftercooler core
    • Air Inlet shutoff
    • Regular duty air cleaner
  • Control System
    • ADEM A3 ECU, left-hand mounted
    • Direct rack control 0-200 mADC, space heater and jacket water heater connection and controls
  • Cooling System
    • Separate-circuit aftercooled
    • Outlet controlled jacket water thermostat
    • Jacket water pump – gear driven
    • Dual outlet
    • Aftercooler water pump – gear driven
    • Aftercooler water thermostat
  • Exhaust System
    • Dry exhaust manifold
    • Dual turbochargers, water cooled bearings
  • Flywheel And Housing
    • SAE No. 00 flywheel
    • SAE No. 00 flywheel housing
    • SAE standard rotation
  • Fuel System
    • Fuel filter simplex (LH) with priming pump (LH)
    • Fuel transfer pump
    • Fuel return line with flexible connection
    • Electronic unit injectors
  • Generator Attachments
    • Barrel-mounted petroleum terminal box with air filter andpressure differential switch
  • Instrumentation
    • Emergency stop button
    • Analog gauges:
    • Service port connector
    • Customer connection terminal blocks
  • Emcp 4.3 Control Panel
    • 140 mm (5.5 in) Graphical Display
    • Communication
    • Controls
    • Generator Set Protection
    • Outputs
    • Inputs
    • Other Features
  • Lubrication System
    • Crankcase breather
    • Oil cooler
    • Shallow oil pan
    • Oil drain extension, 2 in NPT female connection
    • Simplex oil filter
  • Mounting System
    • 4.19 m (165 in) length, 412 mm (16.2 in) height tubes, 1.18 m (50.5 in) wide
  • Protection System
    • Engine alarms, derate, and shutdown in abnormal operation
  • Starting System
    • TDI air starting motor, RH – 1034 kPa (150 psi)
  • General
    • Paint - Cat yellow
  • Air Inlet System
    • Heavy duty air cleaner
    • Remote air inlet adapter – rectangular
    • Remote air inlet adapter – round
  • Control System
    • Engine control options:
    • Load sharing governor, 2301A
  • Cooling System
    • Radiator options:
    • Coolant level sensor
    • Coolant conditioner
    • Cooling system connection options (for use with customer-suppliedradiator):
    • Fan drive and belt guard (for use with remote and customersuppliedradiators)
    • Fan pulley options (for use with customer-supplied radiator):
  • Exhaust System
    • 1200 rpm model only:
    • 1500 rpm model only:
  • Fuel System
    • Custom fuel filter
    • Primary fuel filter
    • Primary fuel filter with water separator
  • Generator Attachments
    • Cable access box
    • Air filter
    • Bearing RTDs
    • Low voltage extension box
    • Manual voltage control
  • Instrumentation
    • Communications module PL1000T
    • Communications module PL1000E
    • Thermocouples installed, one per cylinder
  • Lubrication System
    • Custom oil filter
    • RH installed centrifugal oil filter
    • SAE15W40, Caterpillar DEO, 500 hour
    • Crankcase fumes disposal
    • Oil level regulator
  • Mounting System
    • Bases
    • Vibration isolators, rails
  • Power Take-off
    • Alternator, 24V, 68A
    • Front accessory drive
    • Pulleys
  • Protection System
    • Explosion relief valves (3)
    • Metal particle detector switch
    • Metal particle detector with annunciator
  • Starting System
    • Custom starting motor
    • Air pressure regulator
  • General
    • LH installed engine barring group
    • Jacket water heater, UL recognized, 120-240V, singlephase, 6 kW, LH and RH mounted
    • Jacket water heater, UL recognized, 120-480V, singlephase, 12 kW, LH and RH mounted
    • Jacket water heater lines