Electric Power:

Gas Generator G3512H

Maximum Continuous Rating
1515 ekW / 1505 ekW @1.0pf
Fuel Type
Natural Gas
Maximum Electrical Efficiency
44.90%
Maximum Standby Rating
1515 ekW / 1505 ekW

G3512H Generator Set



Product Specs

  • Generator Set Specifications

  • Maximum Continuous Rating
    1515 ekW / 1505 ekW @1.0pf
    Fuel Type
    Natural Gas
    Maximum Electrical Efficiency
    44.90%
    Frequency
    50 / 60 Hz
    RPM
    1500 rpm
    Speed
    1500 rpm
  • Gas Generator Sets Specification

  • Maximum Standby Rating
    1515 ekW / 1505 ekW
  • Engine Specifications

  • Aspiration
    TA
    Bore
    6.7in
    Displacement
    3574in³
    Engine Model
    G3512H
    Stroke
    8.5in
    Governor Type
    ADEM A4
  • Generator Set Dimensions

  • Length
    223in
    Width
    76in
    Height
    91in
    Dry Weight - Genset
    31085lb

Equipment

  • Air Inlet
    • Package Mounted Air Cleaner with service indicator
  • Cooling
    • Jacket water and SCAC thermostats
    • 2nd Stage CAT Flange
    • ANSI Class 150 JW Connection
    • Engine driven pumps for jacket water and aftercooler cooling
  • Control Panels
    • Dedicated customer wiring terminals
  • Control Panel
    • EMCP4.3
  • Exhaust
    • Dry exhaust manifolds insulated and shielded
    • Center section cooled turbocharger with Cat flanged outlet
  • Generator
    • High efficiency low voltage Cat generator, permanent magnet excitation, digital regulation, IP23 water ingress protection, & form wound construction.
  • Starting/charging
    • Electric Starter
  • General
    • Paint - Caterpillar Yellow except rails and radiators gloss black
    • Crankshaft vibration damper and guard
  • Air Inlet
    • Mounting brackets and piping
    • Air cleaner with precleaner
  • Control Panels
    • Remote annunciator
  • Circuit Breakers
    • Frame mounting circuit breaker orientation
    • 2500A 3-pole IEC rated circuit breakers
    • Rear Mounted Circuit Breaker
    • 3000A/3200A/4000A UL100% Rated Masterpact circuit breaker (60 Hz only)
    • LSI Long-Time, LSI-P Long-Time, LSIG Long-Time, LSIG-P Long-Time,
  • Control Panel
    • Language Options
    • Cable Shroud Location
    • Engine failure relay
    • Discrete I/O module, 12 digital points, 8 'Form C' relay
    • 16 point/32 light annunciator with NFPA99-110/CSA282 configuration
    • Empty Upper Box Right/Left
    • Local Alarm module
    • Synchronization module
    • Cat Connect: Ethernet, satellite, or cell telematics
    • Local/Remote PC Monitorring
    • Right/Left/Rear Extension Box
  • Cooling
    • Remote radiator for JW and SCAC circuits
    • 220V (50Hz), 240V (60Hz), 480V (60Hz) JW heater
  • Exhaust
    • Flexible fitting [305mm x 305mm (12in. X 12in.)] w/ 12 bolt-flanges
    • 406mm (16in.) sparking-arresting muffler with companion flange
    • Exhaust expander [250mm-329mm (10in-12in)]
    • 305mm (12 in.) flange
    • Muffler options
    • Elbow exhaust
  • Fuel System
    • 1/2" NPT gas train conduit connectors
    • 3, 0-100kPag 4-20mA gas train pressure sensors
    • Fuel Filter
    • Gas knockdown regulators
  • General
    • Digital Diagnostic tool
    • US Aid emblem
  • Generator
    • Generator air filter
    • Manual voltage control
    • Cable access box
    • RTD Monitorring
    • Bearing temperature detectors
  • Governing System
    • ADEM A4 4-20mA (0-5V) speed input
  • Starting/charging
    • Battery with cables and rack
    • 24V Starting motors
    • 20A, 24VDC battery charger
    • 45A, 24V charging alternator (requires engine driven pumps)
    • Jacket water heater