Electric Power:

Emergency Transfer Load manager

Emergency Transfer Load Manager
Configuration
Wall mounted paralleling control system that monitors and controls a single generator and a single utility.
Modes of Operation
Utility Import, Export, and base load operations, Peak shaving, and Emergency Standby. Closed Transition to/from Generator Power
Application
LV and MV (208V-32kV)
Operating Temperature
0-50°C

The EXL is a wall mounted system that monitors and controls a single engine generator for operation in parallel with a single utility source. The EXL will support Emergency Standby as well as Utility Paralleling applications.



Product Specs

  • Technical Summary

  • Configuration
    Wall mounted paralleling control system that monitors and controls a single generator and a single utility.
    Modes of Operation
    Utility Import, Export, and base load operations, Peak shaving, and Emergency Standby. Closed Transition to/from Generator Power
    Application
    LV and MV (208V-32kV)
    Configuration
    Wall mounted paralleling control system that monitors and controls a single generator and a single utility.
    Modes of Operation
    Utility Import, Export, and base load operations, Peak shaving, and Emergency Standby. Closed Transition to/from Generator Power
    Application
    LV and MV (208V-32kV)
  • Environmental Parameters

  • Operating Temperature
    0-50°C
    Storage Temperature
    -20°C to +60°C
    Medium Voltage Standards
    NEMA SG-5, ANSI / IEEE C37.20.2, CSA-C22.2 No. 31-M89, EEMAC G8-3.2, NFPA 70, NFPA 99 and NFPA 1110
    Certifications
    IBC, CBC, UBC, & OSHPD Certified
    Control Panel Enclosure
    NEMA 1 or NEMA 3R Freestanding Construction
    Low Voltage Standards
    NEMA SG-5, CSA,ANSI C37.51, ANSI C37.20.1, UL1558 or UL 891, NFPA 110, NFPA 99 and NFPA 70
    Operating Temperature
    0-50°C
    Storage Temperature
    -20°C to +60°C
    Medium Voltage Standards
    NEMA SG-5, ANSI / IEEE C37.20.2, CSA-C22.2 No. 31-M89, EEMAC G8-3.2, NFPA 70, NFPA 99 and NFPA 1110
  • Generator Protective Devices

  • ANSI Protective Devices
    15/25. 27/59, 81 O/U, 32, 40, 50, 51
  • Utility Protective Devices

  • ANSI Protective Devices
    15/25. 27/59, 81 O/U, 32, 40, 47, 51, 86

Equipment

  • Instant Auto Selector Switch
    • Allows user to return sysem to automatic in the event of a touchscreen failure
  • Spare Inputs And Outputs
    • 3 digital inputs and 6 relay outputs programmable from the HMI
  • Supplemental Hardware 25 Device
    • Provides additional discrete synchronization protection